With 25 different voltage settings in both delta and wye connections, multitap transformers are available with either mineral. Instrument transformer basic technical information and. It is utilized in an analogous manner to that of ac instruments, control apparatus, and meters. This transformer step down the voltage to a safe limit value which can be easily measured by the ordinary low voltage instrument like a voltmeter, wattmeter and watthour meters, etc. On subtractive polarity transformers the h1 primary lead and the x1 secondary lead will be on the same. A current transformer or ct is very essential equipment installed in an electrical substation for electrical measurement and protection purpose. Transmission substations can range from simple to complex. They are generally connected directly to overhead utility power lines. The basics of current transformers nk technologies. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load.
Specification substation power transformer standard number. The current transformer is one of the substation equipment used to convert the primary power signal to manageable values for metering systems. Excitation current test determines the current necessary to maintain trans. Circuitbreakers item 6 are designed to provide switching capability. In some, the bar carrying high current may act as a primary. Apr 10, 2020 a transformer substation is a location where electric power is converted from bulk power to local power or vice versa. The largest transmission substations can cover a large area several acreshectares with multiple voltage levels, many circuit breakers, and a large amount of protection and control equipment voltage and current transformers, relays and scada systems. Ideally the current transformers should be on the power source side of the circuit breaker that is tripped by the protection so that the circuit breaker is included in the protective zone in many circuits the power flow can be in either direction and it then becomes necessary to decide which location of fault is most important or likely and to locate the current transformers on the side of. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as current transformer ct and lead remaining undisturbed. K tf values required in practice depend on relay type and design. The input for a distribution substation is typically at least two transmission or subtransmission lines.
Transformer short circuit current calculation and solutions. Operate instruments or metering from high voltage or high current circuits safely isolates secondary control circuitry from the high voltages or currents transformer is connected to the high current circuit, and the meter or relay is. A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer. Medium voltage products technical guide the mvlv transformer. Load loss test determines the amount of losses in the transformer when carrying full rated load. Unless otherwise specified all current transformers ctcts core for protection shall have ratings and performance requirements of relaying including transient. The current transformer is one of the substation equipment used to convert the primary power signal to manageable values for metering systems, recording systems, protective relay systems, power generation, plant monitoring systems. To demonstrate what happens with a second ground on the current transformer circuit, figure 1 shows a typical differential relay with two current transformers.
This is the first component in an electrical substation, and the main function of these components is to protect the components of the substation from passing high voltage as well as stops the amplitude and duration of the flow of current. These transformers reduce the voltage and current from high value to the low value which can be measured by conventional instruments. Current transformers provides a secondary current accurately proportional to the current flowing in its primary. This is connected in series with the line carrying high current. What is the function of the current transformer in a substation.
Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the. The potential transformer with the power read more. The transformer may have differential relaying that trips all of the feeder breakers in the event of a fault. Current transformers, especially those intended for high voltage substation service, may have. High accuracy measurement sensors from 100 to 2000 a. A current transformer ct is a type of transformer that is used to reduce or multiply an alternating current ac.
There is numerous electrical substation components like outgoing and incoming circuitry each of which having its circuit breakers, isolators, transformers, and busbar system etc for the smooth functioning of the system. Low value of impedance may result in large shortcircuit currents, leading to high forces. In this case the current transformer utilizes a moving secondary coil to vary the output so that a constant current is obtained. Electrical substation components, workings and their functions. Recommendations are provided by manufacturers see application guides. Substation distribution transformers small distribution. Street lighting requires a constant current to prevent flickering lights and a current transformer is used to provide that constant current. The 67n relay offers an alternative to the 87n function. Current transformers ct are used in high voltage hv and medium voltage mv 1 installations to give an image of electrical current to protection relays and units and metering equipment and they are designed to provide a current in its secondary proportional to the current flowing in its primary. Pdf a study on the inrush current phenomena in transformer. For the avoidance of doubt this includes evidence of commissioning processes and procedures that ensure that the above requirements are met.
Design of earthing grounding system in a substation grid. Transformers increase voltage, decreasing current in power systems. Traditionally, on load tap changer is a complex mechanical device, which has some. Lower i means less power loss due to i2r losses in lines, cables, transformers, etc generator step up transformer i v step down transformer v i three phase transformers 3 singlephase units can form 3phase bank or single threephase transformer 3 separate cores in a single tank. In reality, however, it is not possible to neglect the excitation. Similarly, current transformers take a high current and reduce it to typically 5 amps on the secondary winding so that it can be used with a watthour meter, ammeter. Validating current and voltage transformer wiring youtube. Substation distribution transformers have covermounted, primary and secondary bushings and can be provided with load tap changers ltc.
The substation design manual is not intended to replace asset management standards, but rather to act as a reference document that crossreferences existing standards and process documentation and plugs any gaps where asset management documentation does not exist. Polarity refers to the instantaneous direction of the primary current with respect to the secondary current and is determined by the way the transformer leads are brought out of the case. A transformer is connected to main bus though a bus coupler. Electric power may flow through several substations between generating plant and consumer, and may be changed in voltage in several steps. Ieee guide for the design and installation of cable. Multitap substation transformer submersible pump eaton. In essence, electrical substations consist of power transformers, circuit breakers, and secondary systems for protection, load control and metering. These losses consist primarily of i2r losses in the primary and secondary winding and ensure that specifications of the transformer design are met. A current transformer is a gadget utilized for the transformation of higher value currents into lower values.
The seller shall include the bid formcompleted exhibit a based off of transformer. A current transformer ct is a type of transformer that is used to measure ac. A study on the inrush current phenomena in transformer substations. Method 1 substation with a single transformer when the plant foresees installation of an. Current transformers are also used for street lighting circuits.
A substation that has a stepup transformer increases the. A distinction has to be made between a metering class and a protection class current transformer. In high and medium voltage air insulated substations ais the electromagnetic field, which causes are the static charges of bare cable and conductors and by the atmospheric conditions surges, induce voltages at nolive parts of the installation that create potential differences between metallic parts and ground and also between different points of. The recommended method of grounding is to install a single ground point at the first point of application switchboard or relay panel of the current transformer secondary circuit. Urban substations are usually built in brick, whereas rural. To start with, both are instrument transformers basically used for measurement and protection purpose in power systems. This is showing three of the five 220 kv66 kv transformers, as well as highvoltage transformer fire barriers, each with a capacity of 150 mva. The instrument transformers like voltage transformer and current transformer are used for connecting the electrical instruments to the measuring instruments. Pdf analysis of on load tap changing transformer for. Fundamentals of modern electrical substations part 1. What is the function of the current transformer in a. Eaton s cooper power series multitap substation transformers increase reliability and flexibility in the field for electric submersible pump esp applications.
Electrical substation components list diagram, working. Short circuit and current capacity of equipment, bus and other equipment compliance with projects scope and requirements number of feeders and load circuits. A small switching station may be little more than a bus plus some circuit breakers. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as current transformer ct and lead.
A highvoltage current transformer may contain several cores, each with a secondary winding, for different purposes such as metering circuits, control, or protection. Institute of electrical and electronic engineers ieee std 4 standard techniques for high voltage testing. Allentown, pa abstract more and more substations are retrofitted with numerical relays, meters and monitoring devices. How to locate current transformers in hv substation eep. Current transformer basics and the current transformer. Distribution substation a distribution substation transfers power from the transmission system to the distribution system of an area. The multitap transformer stepsup the lowvoltage output from a variable speed drive vsd to power pumps. The electricity substation is a network of electrical equipment which is connected in a structured way in order to supply electricity to end consumers.
Housing can accommodate from 1 to 4 separate cores within the head of the unit. Ct used for the measurement of ac current by taking the samples of higher currents of the system. Distribution voltages are typically medium voltage, between 2. Current transformers perform the following functions. Unit substation transformer primary unit substations eaton. A mv lv transformer electrical substation consists, therefore, of the. These elements are part of the transformer protection in that they limit the accumulated damage that occurs from a transformer feeding high current into downstream faults.
Numbers of breakers, disconnect switches, transformers, auxiliaries, protective devices, lines and other equipment. The design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing cable failures and their consequences. Substation layout substation layout single line diagram check. Scribd is the worlds largest social reading and publishing site. Current transformer circuit symbols according to ieee and iec standards. It produces an alternating current ac in its secondary which is proportional to the ac current in its primary. By locating the mediumvoltage transformer and closecoupled equipment near areas of load concentration, the secondary distribution cablesbuses are kept to minimum lengths, resulting in advantages including. A 50 hz electrical substation in melbourne, australia. Figure 3 ferroresonance, main interaction is between cs and lm. They are in turn divided into urban or rural substations, consisting of a single small power transformer. Substation equipment potential transformers used in system for stepping down voltage to a safe value for low rating meters and relays. The 1103510 kwh substation is located in the jalalabad region. The possibility of a subtransmission circuit fault is much higher than a transformer fault. An electrical substation is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers.
Technical guide the mvlv transformer substations abb group. Maintenance of transformers a detailed checklist electrical4u. The seller shall include the bid formcompleted exhibit a based off of transformer unit sheet. These drab gray stations sit at the center of many electrical wires, both above and below ground. A study on the inrush current phenomena in transformer substations conference paper pdf available in conference record ias annual meeting ieee industry applications society 2. Kyrgyzstan prime minister muhamedkaliy abilgaziyev has attended the opening ceremony for the tashbulak substation.
Customer substation manual 6272019 preface page 7 of 82 010. Potential transformer pt definition the potential transformer may be defined as an instrument transformer used for the transformation of voltage from a higher value to the lower value. This substation is constructed using steel lattice structures to support strain bus wires and apparatus. Current transformers, along with voltage or potential transformers, are instrument transformers. The current transformers and accessories covered by this specification shall comply with the requirement of the latest edition of the following standards unless otherwise stated in this specification. Current transformer ct construction and working principle.
The design features and construction details of current transformer. Where separate current transformer accommodation has to be provided, the cost of separately mounted current transformers and also the extra substation space required almost always results in them being located only on one side of the circuit breaker. This bulletin is an update and revision of previous rea bulletin 651, design guide for rural substations revised june 1978. Current transformers ct item 7 measure the current flowing in the respective circuits. Same transformer as in figure 2, energized through a 75.
Accurate devices used to help isolate or transform voltages or current levels. A substation that has a stepup transformer increases the voltage while decreasing the current, while a stepdown transformer decreases the voltage while increasing the. If a current transformer does not perform properly, there may be a huge disturbance in the system due to malfunctioning of protection relays. A study on the inrush current phenomena in transformer. A current transformer ct is a type of transformer that is used to reduce or multiply an. Siemens has proven to be a reliable, trustworthy supplier of highvoltage substations for all voltage levels and for all applications from basic substations with a single busbar to interconnection substations with multiple busbars or a breakerandahalf arrangement for up. Figure 2 unloaded transformer, rated 120v excitation. Primary substation current transformers 11kv through 69kv. Nov 17, 2019 a current transformer or ct is very essential equipment installed in an electrical substation for electrical measurement and protection purpose. Abb is implementing the first commercial installation of. Nov 15, 2019 a current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle which is approximately zero. It produces a current in its secondary which is proportional to the current in its primary. Each distribution voltage the substation supplies must have its own bus.
It is now possible to connect primary highvoltage equipment to abbs fieldproven substation protection and control devices more effectively, improving the reliability and availability of optimized substations. Instrument transformers scale the large values of voltage or current to small. A read is counted each time someone views a publication summary such as the title, abstract, and list of authors, clicks on a figure, or views or downloads the fulltext. In practice this is generally on the circuit side of the circuit breaker. Depending on the function performed, it can be defined as a transforming, conversion, transmission or distribution substation. Eaton s primary unit substation transformer is ideal for stepping down utility distribution voltages to inplant distribution voltages. The result is a voltage of very small magnitude across the operating coil of the relay. Current transformer grounding powell industries, inc. All rus borrowers rus electric staff effective date. So far accurate measurement and smooth operation of an electrical power system, cts must be properly. A current transformer ct basically has a primary coil of one or more turns of heavy crosssectional area. A current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle that is approximately zero.
1655 1186 1281 390 420 1106 267 1280 835 984 1618 1389 1625 538 818 940 1040 263 242 672 930 265 730 313 1300 176 218 1421 904 165 1219 943